Source: Service Manual for 300, 500 and 800 Series Built-in Wall Ovens (Bosch HBL8x50UC, HBL57x0UC, HBL56x0UC, HBL54x0UC, HBL35x0UC, HBL33x0UC, HBN56x0UC, HBN54x0UC, HBN35x0UC, HBN34x0UC, HBN3350UC), section 5.1 Error Code Table
E309 is a ROM check error in the control module, the relay board that runs the elements, fans and latch.
Bosch’s service manual for its 2007 built-in wall ovens (300, 500 and 800 Series) lists E309 as a ROM check error in the control module, with no cause or test beside it. The control module is the relay board in the top of the oven; ROM is the stored program it runs from. At power-up the board checks that data, and E309 says the check failed.
At a glance
| Code | E309 |
|---|---|
| Appliance | Oven |
| What it means | ROM check error in the control module. |
Owner side
The only safe step is a power reset: breaker off for 30 seconds, then on, then set the clock. If E309 returns, leave the oven off. The board is reached from the top of the unit after the oven is slid about 16 inches out of the wall, and nothing on it is user-serviceable.
What the manual tells technicians about this board
- Disconnect and reconnect every wire and harness on the module before deciding it has failed.
- After replacing the module, reset the oven and test it. Sometimes a second reset is needed.
- If the user interface is replaced too, the oven will show E000 until the Option Code is set in Service Mode.
E309 versus E009
Both are ROM check errors, but on opposite boards. E009 is the user interface failing to get all of its start-up information, and the manual points to communication or a loose wire. E309 is the control module’s own check failing, with nothing listed beyond that.
Similar codes
- E310: data memory error on the same board
- E009: the ROM check error on the user interface side
- E000: what appears when both boards are new and not yet configured
E309 repair in San Francisco
Call (415) 851-9513 if E309 comes back after a breaker reset. The model and FD numbers on the plate under the control panel help us order the correct module.